Three numbers that need to be replaced with a new moisture meter

Sep 12, 2023

Leave a message

Three numbers that need to be replaced with a new moisture meter

 

A good hygrometer should be designed for durability, as their operating environment can sometimes be rough.


Delmhorst's hygrometer is known for its durability and long lifespan, which can withstand some of the appropriate care from users (storage, battery, pins, and cleanliness).


However, even the toughest instruments ultimately require repair or even replacement.


There are several different signs that can indicate whether the hygrometer is damaged or not working properly.


However, just because the reading provided by the hygrometer is not good does not necessarily mean it has been broken. Many errors may come from environmental factors or error handling.


Some common factors that affect the reading of moisture meters include the following conditions:


Type of material being tested


Temperature of materials


Types of wood being tested


Low battery


If you determine that the poor reading is not due to any other factors such as measuring materials, batteries, or user errors, then you may need to send the instrument for repair or replacement.


3 signs indicate that your moisture meter is not working

Below we provide some warning signs that you can use to determine if your hygrometer is damaged; I hope this can help you save your wallet and save some time waiting for repairs/replacements.


1. Internal creaking sound

The internal components of the hygrometer should be firmly seated; When you hear a clicking sound while using the device, it is likely that there is a problem. This is usually a good indicator that something in the device has broken or become loose.


2. Readability

Being able to see clear readings on the display screen is an important part of the moisture meter testing process. As we discussed earlier, sometimes when the battery runs out, it can cause the screen backlight to fail or the digital segments on the digital display screen to malfunction.


If you replace the battery with a new fully charged one and still obtain inaccurate readings, internal repair or replacement may be necessary, which may be more severe. In this case, a good choice is to contact the manufacturer of the instrument to solve the problem with a good solution.


3. Not activated

A quick indicator, you should invest in a new hygrometer or your current hygrometer needs to be repaired when it is not activated. Similarly, this may be due to low/depleted battery power, but if you replace the battery and still do not activate it, it may be due to internal component damage, which may require repair or replacement.

 

brick moisture meter 2

 