7mm line detection AC/DC clamp meter features

Feb 26, 2024

Leave a message

7mm line detection AC/DC clamp meter features

 

Power staff for the line to make up for the substation cabinet, wiring complex occasions, automotive power supply testing leakage current. Detection of current, leakage current meter, there are designed for the detection of small volume, high precision, AC and DC testing clamp ammeter. 7mm clamp head is particularly suitable for rows of dense places (power metering system, high-speed rail system, automotive circuit overhaul, DC power supply leakage detection, etc.), is a must-have tool for low-voltage testing and maintenance.


φ7mm line detection AC and DC clamp table features (ETCR6000 AC and DC clamp table):
1, small caliber jaw, small size, high accuracy, stable performance, suitable for narrow space testing, line dense places and automotive power testing


2, there is a zero function, before the test, adjust until the instrument to zero, and then test. Reasonable use of this function will make the measurement value more accurate. Adjust the ZERO key to zero, remove the amount of induced residual magnetism, and then clamp the measured wire. There may be residual magnetism after measuring a high current, so it is necessary to reset to zero before the next measurement. This * maximum testing accuracy.


3, equipped with RS232 interface, and 99 sets of storage data function, testing can be connected to electronic equipment, directly display the test data, easy to analyze the application of the


Microampere current clamp meter to measure leakage current
Microampere clamp ammeter, belongs to the small caliber and small volume clamp meter, the main test of low-voltage line micro-current, current, etc.. It is characterized by small size, high accuracy, easy to carry, small caliber test is convenient, can be connected to a computer to import the data saved by the test, for reference, etc. is the essential clamp meter for low-voltage current testing. Microampere current clamp meter to measure leakage current

Clamp meter test circuit current, must strictly abide by the safety rules, can not be used for more than the upper limit of the range of line current test (range: 0.001mA-60A). Measurement of equipment lead lines, testing equipment conditions, testing the lead fire line, zero line together with the clamp; and testing equipment leakage, only need to test the ground line alone (pay attention to the jaws of the full closure) as follows.


Similarly, if the total current of the main line is tested, only the main line needs to be tested separately. The current drawn by the test equipment is also separately clamped to the main line connecting the equipment

 

Professional clamp meter

Send Inquiry