1. Only the surface temperature is measured, and the infrared thermometer cannot measure the internal temperature.


2. The wavelength above 5um cannot be used for temperature measurement through quartz glass. Glass has very special reflection and transmission characteristics, and infrared temperature readings are not allowed. But the temperature can be measured through the infrared window. Infrared thermometers are best not used for temperature measurement on bright or polished metal surfaces (stainless steel, aluminum, etc.).


3. Locate the hot spot. To find the hot spot, the instrument aims at the target, and then scans up and down on the target until the hot spot is determined.


4. Pay attention to environmental conditions: steam, dust, smoke, etc. It blocks the optical system of the instrument and affects the temperature measurement.


5. Ambient temperature. If the thermometer is suddenly exposed to an ambient temperature difference of 20°C or higher, allow the instrument to adjust to the new ambient temperature within 20 minutes.

Precautions for Infrared Thermometer

Problems that should be paid attention to when using infrared thermometers:

The temperature cannot be measured through the glass.

Only the surface temperature is measured, and the infrared thermometer cannot measure the internal temperature.


Be aware of ambient conditions: steam, dust, smoke, etc. It blocks the optical system of the instrument and affects temperature measurement.


1. In order to avoid damage to the infrared thermometer, please use compressed air first for large particles and dust, and then wipe it with a piece of cloth.


2. Gently use slightly dampened non-corrosive solution or mild diluted soap solution (solution or mild diluted soap solution (do not use soluble soft cotton cloth to wipe the lens (do not immerse the cloth in the liquid) ) wipe the lens with a soft cotton cloth (do not soak the cloth in the liquid). Use a clean computer monitor cleaning cloth to gently wipe the display.


3. Gently wipe the display screen with a clean computer monitor cleaning cloth. To clean the infrared thermometer body: To clean the thermometer body: Gently wipe the thermometer body with a clean, slightly damp cloth.


4. Use a clean slightly damp cloth to gently wipe the body of the thermometer. Dampen the cloth with a solution of water and a little mild soap if necessary. If necessary, dampen the cloth with a solution of water and a little mild soap.


5. After use, please cover the infrared thermometer with the lens cover as soon as possible, and put it away.

 