① Unless otherwise specified during testing, analog multimeters shall not be used to test ECUs and sensors. High‑impedance digital multimeters are required, with an internal resistance of no less than 10 kΩ.

 

② First check fuses, fusible links and connector terminals. Troubleshoot faults at these locations before carrying out multimeter inspections.

 

③ When measuring voltage, the ignition switch shall be turned ON, and the battery voltage shall be no lower than 11 V.

 

④ Take care when removing rubber boots while inspecting waterproof connectors with a multimeter. Do not apply excessive force to the terminals with test probes. For measurement, probes may be inserted from the rear side with wiring or from the front side without wiring.

 

⑤ When measuring resistance, gently wiggle the wire vertically and horizontally to improve measurement accuracy.

 

⑥ To check for open‑circuit faults, first disconnect the ECU and corresponding sensor connectors, then measure the resistance between relevant pins of the connector to identify open circuits or poor contact.

 

⑦ To check for short‑to‑ground faults in wiring, disconnect the connectors at both ends of the wire, then measure the resistance between the connector pin and vehicle ground. A resistance value greater than 1 MΩ indicates no fault.

 

⑧ Before disassembling components of the engine electronic control system, cut off the power supply first: set the ignition switch to OFF and disconnect the battery terminal.

 

⑨ The symbols for ground pins on connectors vary by vehicle model. Refer to the service manual for identification.

 

⑩ When measuring voltage between two terminals or two wiring circuits, connect the two probes of the multimeter (voltage range) to the two measured terminals or two separate wires.

 

⑪ When measuring the voltage of a single terminal or circuit, connect the red probe of the multimeter to the measured terminal or circuit and the black probe to vehicle ground.

 

⑫ Continuity testing of terminals, contacts or wires checks whether they are conductive without open circuits. This is performed by measuring their resistance with a multimeter.

 