Common Failures and Troubleshooting of Digital Multimeters

Nov 23, 2026

Common Failures and Troubleshooting of Digital Multimeters

 

① No display on the meter First, check whether the battery voltage is normal (9 V battery is commonly used; test even brand‑new batteries). Next, check whether the fuse is blown, the voltage regulator is normal, and the current‑limiting resistor is open. Then inspect the circuit board for corrosion, open circuits or short circuits (especially the main power supply circuit). Clean and dry the board promptly if any defect is found. If the circuit board works, measure the two power supply pins of the integrated circuit block. If the supply voltage is normal, the IC block is faulty and must be replaced. If the supply voltage is abnormal, check for other short‑circuit points. Remove short circuits if found. If the fault persists after troubleshooting, the IC block has an internal short circuit and requires replacement.

 

② Resistance range cannot take measurements First visually inspect the circuit board for burnt connections in the resistance measurement circuit. Replace burnt components immediately if present. If nothing is burnt, measure each connected component and replace defective parts. If all external components are intact, the measuring IC block is damaged and needs replacement.

 

③ Incorrect or drifting readings at high voltage measurement in voltage range This fault is usually caused by one or more components working out of specification. If the component becomes hot within seconds during measurement, it is damaged due to insufficient power rating. Replace such a component (or IC block).

 

④ Current range cannot take measurements Most such faults result from improper operation. Check whether the current‑limiting resistor and voltage divider resistor are burnt; replace burnt resistors. Then check whether the wires connected to the amplifier are damaged; reconnect them if broken. Replace the amplifier if readings remain abnormal.

 

⑤ Unstable readings and flickering digits Check if the circuit board is damp or leaking electricity. Clean and dry the circuit board thoroughly if so. Check for poor contact in input circuits (such as selector switches and test jacks). Resolder loose connections. Check for component degradation or thermal drift after power‑on, which causes parameter drift. Replace any defective components found.

 

⑥ Inaccurate readings This is caused by failed resistors or capacitors in the measurement circuit; the faulty resistor or capacitor must be replaced. Check resistors in the measurement circuit (including feedback resistors). Replace resistors with shifted or unstable resistance values. Check resistors and capacitors in the reference voltage loop of the A/D converter; replace damaged ones.

 