Electromagnetic acid-base concentration meter detailed introduction

Dec 12, 2022

Leave a message

Electromagnetic acid-base concentration meter detailed introduction


Electromagnetic acid-base concentration meter detailed introduction


BM73-CYN-1E electromagnetic acid-base concentration meter is an on-line industrial analysis instrument, suitable for installation in the regeneration liquid pipeline or submerged in the acid-base dilution tank. The electromagnetic acid-base concentration meter is mainly used in the process of producing high-purity water by ion exchange to monitor the concentration of the regeneration solution of the ion exchanger. It uses the principle of electromagnetic induction to avoid the corrosion, pollution and polarization effects of strong corrosive solutions such as acids and alkalis on the electrodes. The electromagnetic acid-base concentration meter can read the concentration value on the spot and monitor it remotely. It can cooperate with the computer or the adjustment device to realize the optimal concentration adjustment of the regeneration program control, which can greatly improve the regeneration effect of the ion exchanger and avoid calcium formation on the cation bed. , Accidents caused by silica gel on the cloudy bed, ensuring the safe and economical operation of the ion exchanger. Electromagnetic acid-base concentration meter can be used in electric power, chemical industry, metallurgy, food, pharmaceutical and other industries for high-precision and continuous monitoring of the concentration of various strong electrolytes such as HCl, H2SO4, NaOH, and NaCl.




Electromagnetic acid-base concentration meter technical indicators


Range: NaOH0~5.00%; HCl 0~10.00%; NaCl 0~5.00% (weight percentage)


Accuracy: Class 5.0


Electromagnetic acid-base concentration meter Measuring medium: HCl, NaOH, NaCl (specified when ordering, negotiated when ordering other media)


Temperature compensation range: 5~55℃


Immersion sensor working pressure: ≤0.6Mpa


Temperature sensor: AD590 (298.15mA/25°C)


Electromagnetic acid-base concentration meter display mode: 4-digit 0.8-inch LED display, three-digit effective value of the concentration.


Output mode: DC 4~20mA standard signal (DC 0~20mA or DC 0~10mA output signal can be ordered).


Output maximum load resistance: 500W


Output constant current performance: equivalent internal resistance>40MW


Controller power supply: DC24±3V, power consumption 0.2A.


Controller installation method: wall-mounted.


Immersion sensor installation form: see attached picture 2


Controller dimensions: 165×165×100mm3


Electromagnetic acid-base concentration meter controller weight: 0.7kg


3. Portable ph meter

Send Inquiry