Guidelines for the daily use of biological microscopes

Mar 25, 2024

Leave a message

Guidelines for the daily use of biological microscopes

 

Maintenance of the biological microscope
After adding a coverslip, the surface of the specimen will be even, and the light will be concentrated, making it easy to examine.
When the microscope is taken out of the wooden box or packed in a box, hold the arm of the microscope tightly with your right hand, hold the microscope base firmly with your left hand, and take it out gently. Do not use only one hand to remove the microscope to prevent it from falling, and then gently place it on the bench or into a wooden box.


When placing the microscope on the practical table, put one end of the lens holder first, then put all the lens holders steadily, and do not make the lens holders contact with the table surface at the same time, as this will cause too much vibration, and the lens and micro-adjuster devices will be easily damaged.
The microscope must be kept clean frequently, do not make oil and dust attached. If the lens part is not clean, use the mirror paper to wipe lightly, if there is oil, first dip the mirror paper into a little xylene to wipe away.
The microscope can not be exposed to the sun and use.


The eyepiece and the objective lens should not be extracted and unloaded casually. When the eyepiece must be extracted, the upper mouth of the lens barrel should be covered with a cloth to avoid the dust falling into the lens barrel. When replacing the objective lens, it should be inverted under the clean table after unloading, and then loaded into the tube of the wooden box where the objective lens is placed.
After the microscope is used up, remove the specimen piece, through the concentrator down, and then turn the objective lens into a "eight" shape, turn the coarse adjuster to make the mirror tube down, so as not to contact the receiving lens and the concentrator.
Biological microscope should be placed in a dry place to prevent mould.


Mechanical stage focusing limit to prevent accidents
The focus position can be locked, making it easier to refocus after changing samples. When the upper limit of the stage is locked, accidental contact between the objective lens and the carrier film is avoided, thus preventing damage to the object and the objective lens.


Specially Designed Pins Keep Binocular Observation Tube Dropped
With conventional microscopes, the binocular barrel can sometimes fall off when it is rotated. However, the CX22 series, equipped with a specially designed pin, effectively eliminates this concern. The eyepieces, objective lenses, objective dial, and other parts are also secured to the microscope stand preventing them from falling off or being lost during transport.


Grab the coaxial handle for smooth focusing
The coarse focusing torque can be adjusted to meet viewer preferences and usage needs. A coaxial focusing knob allows operation from the left or right side of the coarse and fine focus adjustment.

 

4 Larger LCD digital microscope