+86-18822802390

How to maintain and maintain the clamp meter

Nov 29, 2022

How to maintain and maintain the clamp meter


(1) When using a high-voltage clamp meter, attention should be paid to the voltage level of the clamp ammeter, and it is strictly forbidden to use a low-voltage clamp meter to measure the current of the high-voltage circuit. When measuring with a high-voltage clamp meter, it should be operated by two people. Non-duty personnel should also fill in the second work ticket when measuring. They should wear insulating gloves when measuring, stand on insulating mats, and do not touch other equipment to prevent short circuit or grounding.


(2) When observing the timing of the watch, special attention should be paid to maintaining a safe distance between the head and the live part. The distance between any part of the human body and the live body should not be less than the entire length of the clamp meter.


(3) When measuring on a high-voltage circuit, it is forbidden to use wires to connect the clamp ammeter to another meter for measurement. When measuring the current of each phase of the high-voltage cable, the distance between the cable ends should be more than 300mm, and the insulation should be good, and the measurement can only be carried out when it is considered convenient.


(4) When measuring the current of low-voltage fusible fuses or horizontally arranged low-voltage busbars, the fusible fuses or busbars of each phase should be protected and isolated with insulating materials before measurement to avoid short-circuit between phases.


(5) When one phase of the cable is grounded, it is strictly forbidden to measure. Prevent personal safety from being punctured and exploded due to the low insulation level of the cable head.


(6) Pull the switch to the maximum range after the measurement of the clamp ammeter to avoid accidental overcurrent during the next use; and it should be stored in a dry room.


4 -