Over-current protection for switch mode power supplies

Apr 16, 2024

Leave a message

Over-current protection for switch mode power supplies

 

Protection of DC switching power supply
Based on the characteristics of DC switching power supply and the actual electrical condition, in order to make the DC switching power supply work reliably in the harsh environment and sudden failure, this paper designs a variety of protection circuits according to different situations.


Overcurrent protection circuit
In the DC switching power supply circuit, in order to protect the adjustment tube in the circuit short-circuit, the current increases not to be burned. The basic method is that when the output current exceeds a certain value, the adjustment tube is in reverse bias state, thus cutting off, automatically cut off the circuit current. As shown in Figure 1, the overcurrent protection circuit consists of transistor BG2 and voltage divider resistors R4 and R5. Circuit normal operation, through the pressure of R4 and R5, making the base of BG2 potential than the emitter potential is high, the emitter junction to withstand the reverse voltage. So BG2 is in the cut-off state (equivalent to open circuit), no effect on the voltage regulator circuit. When the circuit is short-circuited, the output voltage is zero, the emitter of BG2 is equivalent to ground, then BG2 is saturated conduction state (equivalent to a short circuit), so that the regulator BG1 base and emitter is close to short-circuit, and is in the cut-off state, cut off the circuit current, so as to achieve the purpose of protection.


Overvoltage protection circuit
The overvoltage protection of switching regulator in DC switching power supply includes input overvoltage protection and output overvoltage protection. If the switching regulator used by the unregulated DC power supply (such as batteries and rectifiers) if the voltage is too high, will lead to the switching regulator can not work properly, or even damage the internal components, so switching power supply is necessary to use the input overvoltage protection circuit. Figure 3 for the transistor and relay protection circuit, in the circuit, when the input DC power supply voltage is higher than the breakdown voltage of the regulator diode value, the regulator breakdown, there is a current flow through the resistor R, so that the transistor T conductive, the relay action, normally closed contact disconnect, cut off the input. Input power polarity protection circuit can be combined with input overvoltage protection to form a polarity protection identification and overvoltage protection circuit.

 

adjustable power supply