Problems with Combustible Gas Detectors: Their Causes and Solutions

Jul 15, 2023

Leave a message

Problems with Combustible Gas Detectors: Their Causes and Solutions

 

There are two reasons for the failure of the comprehensive combustible gas detector: the construction process is not standardized and the maintenance is not in place. Both of them are possible factors that lead to the failure of the combustible gas detector. Irregularities in the construction process will cause the flammable gas detector to detect failures during use. If the combustible gas detector is not installed near the equipment that is prone to leaking combustible gas, or is installed adjacent to the exhaust fan during installation, the leaked combustible gas cannot be fully diffused to the vicinity of the Gas detector detection.


The combustible gas detector in the residence should be installed near the gas pipeline and stove in the kitchen. When the household uses natural gas, the gas detector should be installed on the ceiling within 300mm from the ceiling; when the household uses liquefied petroleum gas, the gas The detector should be installed within 300mm from the ground. If the flammable gas detector is not reliably grounded and electromagnetic interference cannot be eliminated, the voltage will be affected and the detection data will be inaccurate.


Therefore, the flammable gas detector should be reliably grounded during construction. The flammable gas detectors and terminals are installed in places that are prone to collision or water ingress, which may cause electrical circuit breaks or short circuits. Non-corrosive flux must be used for welding, otherwise the corrosion at the joint will separate or increase the line resistance, which will affect the normal detection. Do not drop or drop the detector on the ground. Debugging should be carried out after construction to ensure that the combustible gas alarm is in normal working condition.


The maintenance of the combustible gas detector is also very important. Due to the harsh working environment of flammable gas detectors, many are installed outdoors and are often attacked by various dust and polluting gases. To detect flammable gas information, the flammable gas detector must communicate with the detection environment Therefore, it is unavoidable for various polluting gases and dust in the environment to enter the detector, and the damage to the working conditions of the detector is objective. If maintenance is not paid attention to, the detection of combustible gas alarms will be blocked. This can lead to errors or non-detection situations. Therefore, regular cleaning and maintenance of the flammable gas detector is an important task to prevent failure.


Another thing to pay attention to is that the grounding should be checked regularly. If the grounding does not meet the standard requirements, or is not grounded at all, it will also make the flammable gas detector susceptible to electromagnetic interference and cause failure. Prevent components from aging. From the perspective of reliability, at the same time, practice has proved that the failures caused by component aging tend to increase in the system of flammable gas detectors with a service period of more than 10 years. Therefore, if the service period exceeds the requirements of the use regulations, it should be replaced in time.

 

Natural Gas Leak finder -