Seven advantages of digital biological microscope
A digital microscope is a microscope with a camera as a receiving element. A camera is installed on the real image surface of the microscope. Through this photoelectric device, the optical image is converted into an image of an electrical signal, and then the size detection, particle counting, etc. are performed on it. Digital microscope And it can be used in conjunction with a computer to realize synchronous preview. The following two pictures are digital biological microscope and digital metallurgical microscope.
Digital Biological Microscope Digital Metallographic Microscope
Digital microscopes have important uses in biology, medicine, industrial and agricultural production.
Digital microscopes have the following advantages over general optical microscopes:
1. With deep synthesis and 3D display functions
2. Using the zoom lens can easily adjust the magnification
3. There is no need to disassemble, cut, process, etc. the observed object
4. Can be observed from any direction and any angle
5. Complete lighting system requires no set-up time
6. Can store images directly
7. Multiple people can observe real-time images at the same time
Common faults and troubleshooting methods
(1) The field of view is blurred or there is dirt. The possible reason is that there is dirt on the specimen, the surface of the eyepiece, the surface of the objective lens, or the surface of the working plate. According to the actual situation, the dirt on the surface of the specimen, eyepiece, objective lens and working plate can be cleaned.
(2) The possible reason for the misalignment of the two images is the incorrect adjustment of the interpupillary distance, and measures to correct the interpupillary distance can be taken. The misalignment of the double images may also be due to the incorrect diopter adjustment, which can be adjusted again, or the left and right eyepieces may have different magnifications. Check the eyepieces and reinstall the eyepieces with the same magnification.
(3) If the image is not clear, it may be that there is dirt on the surface of the objective lens, please clean the objective lens. If the image is not clear when zooming, it may be that the diopter adjustment and focus are not correct, and the diopter adjustment and focus can be re-adjusted.
(4) If the bulb often burns out and the light flickers indefinitely, it may be that the local voltage is too high, the bulb is about to burn out, or the wire connection is short-circuited. Please carefully check whether the voltage and the wire connection of the microscope are secure. The abnormality may be that the bulb is burning out, which can be solved by replacing the bulb.