Smart (AUTO) measurement
This measurement mode is default when power on. In this mode, DC voltage, AC voltage, resistance, continuity can be measured, and the meter can automatically identify the measurement signal.
1) Press POWER ON key to power on, display AUTO and enter the intelligent measurement mode.
2) Insert the red probe into “ INPUT ” jack and the black probe into the “COM” jack.
3) Contact the probe of the probe with both ends of the measured power supply or resistance (parallel), and the meter will automatically recognize the measured signal.
4) When measuring the resistance, the resistance value is less than about 50 Ω The buzzer sounds and the indicator light is on。
5) Read the results from the display.
NOTE:The minimum measurable voltage of this mode: 0.8V
GVDA New Digital Multimeter T-RMS Auto Range AC DC NCV Color LCD Smart Multimetro Tester Ohm Capacitance Hz Temp Voltage Meter GD119B: