Technical indicators of differential pressure gauge
Ambient temperature: -70 ~ 60°C
Rated pressure: -68 ~ 103KPa
Overpressure: The rubber overpressure plug is flushed open at about 172KPa.
Process connection: high pressure and low pressure holes are 1/8" vertebral canal thread, two sets (one set on the side and one set on the back)
Housing material: Die-cast aluminum, main body and chromized aluminum parts after 168 hours salt bath test, external final coating dark gray.
Accuracy: ±2%FS at 21°C (-125PA; 3% for 250PA type, 4% for -60PA type)
Standard accessories: 2 1/8 NPT plugs, 2 1/8″ threaded rubber pipe joints, and 3 flush-mounted screw clips with screws (also tables for MP and HP options, with mounting rings and snap ring retainers replace the above 3 screws)