The fluid solenoid valve tells the application range of the thermometer

Jul 30, 2023

The fluid solenoid valve tells the application range of the thermometer

 

The infrared thermometer is non-contact, light in weight, durable and easy to use. At the same time, the infrared thermometer provides accurate temperature values with an accuracy of 1-4%, and the longest temperature measurement distance can reach 180 feet. Making it a cost-saving diagnostic and preventative tool in electrical system and equipment maintenance inspections. Humidity Sensor Probe , , Stainless Steel Electric Heating Tube PT100 Sensor , , Cast Aluminum Heater , Heating Ring Fluid Solenoid Valve


In the electrical field, infrared thermometers prevent equipment failure and unplanned downtime in the following applications.
1. Connector - The electrical connection part will be loose due to connection points; repeated heating (expansion) and cooling (shrinkage); dust, carbon deposition and corrosion and other factors will generate heat. Non-contact infrared thermometers quickly identify abnormal temperature rises, alerting equipment to serious problems.


2. Motor - In order to prolong the service life of the motor, always check the power connection and the temperature of the circuit breaker (or heater) for abnormalities.


3. Motor bearings – the detection of bearing points can monitor the change of hot spots before the equipment fails, and carry out planned maintenance or replacement parts in advance.


4. Motor winding insulation – Infrared thermometer measures the temperature of motor winding insulation to maximize the service life of winding insulation.


5. Phase-Phase Measurement – By monitoring the phase-phase temperature of cables and connectors of induction motors, mainframe computers and other equipment, it can be used to judge the temperature difference.


6. Transformers – Check the winding temperature of air-cooled units for hot spots indicating winding defects.


7. Uninterruptible power supply – detect the local hot connection in the UPS output filter, if there is a cold spot, it may indicate that the DC filter circuit is open.


8. Backup battery – monitor the correctness of the low-voltage battery connection to prevent the connected battery from heating up and causing the terminal post to burn.


9. Ballast – check in advance to prevent the ballast from overheating and burning out.


10. Public equipment - Infrared thermometers can handle the connection parts of equipment, cable joints, transformers and other hot spots of equipment with ease.

 