+86-18822802390

What are the methods and precautions for using the wood moisture meter

Mar 22, 2023

What are the methods and precautions for using the wood moisture meter

 

How to use wood moisture meter and precautions, wood moisture meter can be divided into pin type wood moisture meter and induction wood moisture meter.


How to use the wood moisture meter:


1. Gear setting method: first press the gear setting button (SPECIES), and then press the test button (TEST). At this time, the current gear value is displayed. Press the setting button continuously to change the gear continuously until needed. stalls.
2. Check before measurement: Set to level 5 according to the above method, then pull out the cap of the instrument, touch the probe on the instrument to the two contacts on the cap, press the test key, if the display is 18±1, it means The instrument is normal.
3 Measurement: Insert the probe on the instrument into the wood specimen to be measured. Press the test button, the value displayed by the instrument is the average moisture content of the test piece, when the water content of the test piece is less than 3, it will display 3.0, and when the water content of the test piece is greater than 40, it will display 40, which means it has exceeded the range.


Precautions for wood moisture meter:


1. When using the instrument for the first time, you can change the gear measurement according to the empirical range value of wood moisture. Whichever gear has the smallest error, you can use this gear for future measurements.


2. If the wood moisture to be measured is unknown, the gear can be determined as follows:
First take a wood sample with relatively average water content, measure the water content with the instrument at levels 1-7, and record the measured values of each level. Then the samples were sent into the oven, and the moisture content was determined by the oven drying method. Then compare with the average value of 7 groups, which gear has the measured value close to it, and then the measurement will be fixed at this gear. If the above measurement is unconditional, it is usually recommended to perform the measurement on the 5th gear. However, attention should be paid to the measurement error caused by this.

 