+86-18822802390

What factors are affected by the gas detector in use?

Nov 24, 2022

What factors are affected by the gas detector in use?


In large industrial sites such as petroleum, chemical industry, power electronics, coal, medicine, metallurgy, pipe gallery, etc., various flammable gases and toxic gases will be produced, which not only endanger people's health, but also affect the production efficiency of the factory and cause unnecessary losses . Gas detectors can detect the concentration of toxic and harmful gases in real time, and are essential safety equipment in factories.


1. Appearance and functional inspection


1. Detect appearance and other items


Checking the appearance is the first thing we do after purchasing the gas detector. This is to avoid minor problems in the transportation or assembly process of the gas detector. We need to check whether the appearance of the gas detector is flawed, cracked or damaged. , Check whether the entire structure of the gas detector is complete.


At the same time, check the machine model, label, manufacturer name, and delivery time on the gas detector body. Check these with the manual or the information given by the manufacturer to ensure accuracy. At the same time, check the explosion-proof marks and measurement of the gas detector. The contents such as the license mark and number must be complete and clear, and some certificates can be provided by the manufacturer.


2. Power-on inspection


The gas detector needs a power supply to work, and it is usually powered by a built-in battery. We need to turn on the switch to check whether the gas detector is powered on normally. Some gas detectors continue to work by replacing the battery, and some gas detectors The detector is equipped with a charger. For the gas detector equipped with a charger, we need to test whether the charger is charged normally. If the power is normal, we need to check whether the display screen of the gas detector is normal.


3. Check whether the sound and light alarm of the instrument is normal


For gas detectors with sound and light alarm signals, because they are powered by batteries, when the undervoltage is displayed, they should be able to send out sound or light indication signals that are clearly different from the alarm signal.


2. Indication error


We buy gas detectors to detect gas concentrations. Gas detectors cannot be very accurate in displaying gas concentrations. There are errors, but this error has a range. If it exceeds this range, it means This gas detector does not meet the standard, and the indication error specified by it is different for different gases. For example, it is normal for the indication error of oxygen to be within ±0.5%VOL.


3. Alarm error


We mentioned the error of the displayed value above, so there is a certain allowable error for the alarm value of the gas detector, because the instrument will be affected by various factors, it is impossible to alarm at an accurate concentration every time, Therefore, the concentration of the alarm is allowed to have errors, as long as the errors are within the standard range. Its alarm error is also different for different gases, for example: the alarm error of oxygen is within ±0.1%VOL.


4. Response time


Response time refers to the time required for the indication value of the gas detector to rise from zero to 90% of the stable indication value that the instrument should reach. This time is also required by the standard. This standard is the same as the indication error and the alarm error. Different gases respond differently. For example, the response time for oxygen is less than or equal to 20S.


5. Insulation withstand voltage


For gas detectors, there are some insulation withstand voltage standards that must be met. The standard requirements: at room temperature: ≥100MΩ; after damp heat: ≥1MΩ. The dielectric strength should be able to withstand 500V AC voltage for lmin, and discharge and breakdown should not occur. Only after these are met can the gas detector meet the standard.


The gas detector is the guarantee of safe production and the guardian of the workshop. Once a gas leak occurs, it will immediately send out an audible and visual alarm after exceeding the preset value, so as to avoid threats to the personal safety of workers and the safety of workshop property. It is indispensable in production and life. Indispensable safety equipment.


7. Natural gas leak detector

Send Inquiry