+86-18822802390

9 key points of gas detector

Dec 01, 2022

9 key points of gas detector


What kind of gas does the gas detector detect?


There are many types of gas detectors, which can meet the specific needs of different customers, so as to meet the needs of users everywhere. The four-in-one gas detector can detect combustible methane, oxygen, hydrogen sulfide and carbon monoxide at the same time. If the four standard gases are not detected at the customer's site, they can be flexibly configured according to the specific type of gas to be detected to truly meet the user's scenario.


What are the digital standards for gas detectors?


The numerical standards of gas detectors can be divided into combustible gases and toxic gases. The detected gas concentrations are different, and the numerical standards are also different. The numerical standard of combustibles is LEL, and the upper and lower alarm limits are 25% and 50% respectively. It can be flexibly configured according to the detection requirements of specific places. The value standard of the toxic gas detector is ppm, and the upper and lower limits of the alarm need to be set according to the specific gas detected.


Generally speaking, if there is no special requirement, these digital standards are set by the manufacturer before leaving the factory, and no manual setting is required. They can be installed directly or portable, and the operation is very simple.


What is the purpose of the gas detector?


The use of gas detectors is very simple, mainly depends on the type of gas detector. The premise of using a fixed gas detector is to ensure its correct operation. It can detect continuously for a long time after power on. Since various parameters have been set before leaving the factory, no other operations are required. Of course, it can be flexibly set according to the specific requirements of the manufacturer.


The use of the portable gas detector is also very simple. There are four buttons. Press the power button, wait for initialization, and the carrier can go to the location to be tested for detection. Generally, the detection speed is faster and the sensitivity is higher in places where the gas concentration is easy to leak. When the upper and lower limits of the alarm are reached, the alarm will prompt the security personnel to do a good job in safety.


What is the best gas detector brand?


There are many brands of gas detectors, each with its own advantages and disadvantages. Over time, there will be more and better brands of gas detection.


What is the normal value of the gas detector?


The normal value of the gas detector usually needs to be kept at the lower limit of the alarm. There is no alarm, and the gas concentration is within the normal safe range. It is safe and works fine, construction and mining. As long as the upper and lower limits of the alarm are exceeded and the gas detector has an alarm prompt, protective measures must be taken in time to avoid any potential safety hazards and cause immeasurable and irreparable losses.


1. gas detector

Send Inquiry