Are Digital Multimeters Able to Replace Analog Multimeters?

Nov 18, 2026

Are Digital Multimeters Able to Replace Analog Multimeters?

 

Undoubtedly, the multimeter is the most commonly used electronic measuring instrument for electricians. Whether to choose a digital multimeter or an analog (pointer‑type) multimeter remains a question. Some people believe digital multimeters are gradually replacing analog ones, yet many veteran professional electricians still prefer analog multimeters. What are the differences between digital and analog multimeters, and which one is better suited for use?

 

The most prominent difference between digital and analog multimeters lies in readout display. Digital multimeters adopt LCD screens with high resolution, fundamentally eliminating parallax during reading and delivering comparatively accurate measured values. While analog multimeters cannot match this advantage, they have their unique merit: the instantaneous deflection of the pointer can intuitively reflect the dynamic change of the measured quantity.

 

Since digital multimeters sample and display readings intermittently, they are not ideal for observing continuous variations and changing trends of the measured signal. For instance, when testing the charging process of a capacitor, the resistance change of a thermistor with temperature, or the resistance variation of a photosensitive resistor with light intensity, analog multimeters offer greater convenience and intuitive observation.

 

There are also differences in working principles. An analog multimeter consists of a meter movement, resistors and batteries. Its meter movement is generally a moving‑coil DC ammeter. The internal battery is only used for resistance measurement, in which case current flows out from the black test lead and back into the red test lead. For DC current measurement, shunt resistors are connected in parallel by range switching to extend the measurement range, because the full‑scale current of the meter movement is very small. For DC voltage measurement, resistors are connected in series with the meter movement; different series resistors provide different measurement ranges.

A digital multimeter is composed of a functional converter, an A/D converter, an LCD display, a power supply and a function/range selector switch. The ICL7106 dual‑slope integrating A/D converter is widely adopted. The ICL7106 performs two integration phases: the first integrates the input analog voltage Vin (signal integration phase), and the second integrates the reference voltage (Vref integration phase, comparison phase). A binary counter counts the duration of the two integration phases and converts the result into a digital value for display. Additional converters are required to measure AC voltage, current, resistance, capacitance, forward voltage drop of diodes, transistor amplification factor and other electrical parameters, so as to convert the measured signals into DC voltage for sampling.

 