Common Troubleshooting Techniques for Digital Multimeters
① Visual Inspection Touch the battery, resistors, transistors and integrated circuits by hand to check for excessive temperature rise. If a newly installed battery becomes hot, a short circuit may exist in the circuit. In addition, check the circuit for broken wires, desoldering and mechanical damage.
② Measurement of Working Voltage at Each Stage Measure the working voltage at each test point and compare readings with nominal values. First of all, ensure the accuracy of the reference voltage. It is recommended to use another digital multimeter of the same or similar model for measurement and comparison.
③ Waveform Analysis Use an electronic oscilloscope to observe the voltage waveform, amplitude and period (frequency) at key circuit nodes. For example, check whether the clock oscillator starts oscillation and whether its oscillation frequency is 40 kHz. If the oscillator has no output, the internal inverter of the TSC7106 may be damaged, or an external circuit may be open. The waveform at pin 21 of the TSC7106 should be 50 Hz; otherwise, the internal divider by 200 may be faulty.
④ Measurement of Component Parameters Perform in-circuit or out-of-circuit measurements on components within the faulty area and analyze parameter values. When measuring a resistor while it remains in the circuit, take into account the influence of components connected in parallel with it.
⑤ Troubleshooting of Intermittent Faults Intermittent faults refer to faults that occur sporadically, causing the meter to work erratically. Such faults are relatively complicated. Common causes include cold solder joints, loose connections, loose connectors, poor contact of the rotary switch, unstable component performance, and nearly broken leads. External factors may also trigger these faults, such as excessive ambient temperature, high humidity or nearby intermittent strong interference signals.