Digital Storage Oscilloscope Module Parameters

Jan 09, 2024

Leave a message

Digital Storage Oscilloscope Module Parameters

 

The Digital Storage Oscilloscope Module is a C-size, dual-slot message-based two-channel digitising oscilloscope (DSO) with 500MHz bandwidth and 1GSa/s sampling rate, suitable for most electronic measurement situations. The internal multiprocessor enables a faster display with an analogue oscilloscope-like feel. The long storage depth of 32KB per channel enables more, faster and better test problems to be solved compared to typical DSO modules with only 1 to 2KB storage depth.


Digital Storage Oscilloscope Module Features
Wide bandwidth, high sampling rate, deep storage


●Peak detection, burr trigger


●Pulse parameter automatic test


●0~40℃ working temperature range


Digital Storage Oscilloscope Module Parameters
Acquisition System Maximum Sampling Rate 1GSa/s Maximum Equivalent Sampling Rate 250GSa/s Vertical Resolution 8bit Record Length 64Kpts/ch (Single Channel 64Kpts) Vertical System Bandwidth (-3dB) 50Ω Input: DC ~ 500MHz (10mV/div ~ 1V/div) DC ~ 250MHz (≤5mV/div) 1MΩ Input: DC~250MHz(≤500mV/div) DC~200MHz(>500mV/div) Real-time bandwidth DC~250MHz Rise time 50Ω Input: <700ps(10mV/div~1V/div) <1.2ns(≤5mV/div) 1MΩ Input: <1.2ns(≤500mV/div ) <1.75ns(>500mV/div) Upsurge 50Ω input: <5%(10mV/div~1V/div) <8%(≤5mV/div)1MΩ input: <8% Number of Channels 2+1 Deflection Factor 1mV/div~1V/div, 1, 2, 5 Step (50W input) 1mV/div~5V/div, 1, 2, 5 Step (1MW input) △V measurement error ±(1.25% fullness + 2% reading + 1LSB + 0.5mV) Offset range ±1V (2mV ~ 100mV/div) ±10V (200mV ~ 1V/div) ±100V (2V ~ 5V/div) Horizontal system time base range 200ps/div ~ 5s/div, 1, 2, 5 step Time base accuracy <50ppm Delay range Pre-trigger: not less than 10 frames Post-trigger: max. 50s △t Measurement error ± (50ps + 0.01% x △t reading + 0.2% x screen width) Time resolution 4ps Reference point position can be set to the left, centre or right of the display Trigger system within the trigger sensitivity 0.5div (DC ~ 20MHz) 1div ( 20MHz ~ 100MHz) 2div (100MHz ~ 500MHz) external trigger sensitivity <50mV (DC ~ 500MHz) trigger level range ± 8 frame trigger jitter <200ps (peak-to-peak) trigger mode along the trigger, logic combinations (pattern) trigger, burr trigger trigger source can be selected ch1 ~ ch2, EXTtrig, EXT _ TTL, VXI trigger bus burr trigger minimum burr detection width of 8ns burr width resolution of 2ns narrowest trigger pulse 1ns Functional characteristics of the automatic scale requirements of the signal: duty cycle> 5%, amplitude> 10mVpp, frequency in the range of 50Hz ~ 300MHz and the relative stability of the signal cursor measurement of the dual-voltage cursor and dual-time cursor, can be measured manually can also be automatic tracking Measurement of automatic pulse parameters measurement frequency, period, pulse duration, rise time, fall time, pulse amplitude, positive pulse width, negative pulse width, pre-shoot, overshoot, duty cycle, RMS voltage General characteristics of the device type of message-based device address setting mode dynamic device, logical address auto-configuration device addressing configuration register data width D16, A16 address space.FDC Data Width D32, A32 address space MODID line support Trigger capability TTL trigger, ECL trigger Plug & Play capability Complies with VXIplug & play specification for Win98 platform. Instrument drivers and soft panels comply with Plug & Play specifications. Power consumption less than 150VA Operating temperature 0 ℃ ~ 40 ℃ Volume 62 (W) × 250 (H) × 340 (D) mm Weight about 2.1kg

 

GD188--2 12MHz Bandwidth Oscilloscope Multimeter

Send Inquiry