Do I need to zero when turning on the gas detector

 

Is it necessary to "zero" the portable gas detector every time it is turned on and used. This is actually a great question, so what exactly is the zero adjustment step? As a standard process, perform four basic steps in clean air each time the instrument is opened.


1. Confirm battery level


2. Zeroing


3. Bump test


4. Clear Peak


Do you need to adjust zero? There are several points to note:

1) The key to zero air is to know that you are in clean air. Unless you know that you are in a clean air environment, you should not zero the instrument. Zeroing the instrument in the polluted atmosphere may lead to confusion of readings, and may even mask the readings of potentially dangerous gas concentrations.


2) If zero adjustment is necessary, but the surrounding environment is near a fire or in a smoky area without clean air, you should use zero air (compressed air to remove impurities) to establish a standard for your detector. Zero air will not damage the functionality of your detector or interfere with the sensor.


In an unclean air environment, if the instrument is turned on and the combustible and toxic gas sensors read 000, and the oxygen sensor reads 20.9, what is the purpose of zeroing the gas detector? Assuming that your gas detector did not intentionally mask negative readings, it is not beneficial to zero at this point. So, if you turn on your instrument and the reading is normal or within your acceptable range, there is no need to waste time completing the zero adjustment process. You will not become better or safer as a result.

But if you are preparing to zero, please ensure that you are doing so in a clean air environment.

 