How to correctly install the harmful gas detector

 

Out of safety considerations, many people will install toxic and harmful gas detectors in places where flammable gases are used, which also has a certain safety warning function, so how to properly install toxic and harmful gas detectors? It is easy for everyone Let me introduce to you guys:

In natural gas, crude oil, chemical plants, coal and other fields, combustible gas is one of the common gases, and it is also a gas that is often used. Toxic and harmful gas detectors have also become necessary experimental instruments. In places where combustible gas is used or where there is leakage of combustible gas, according to the corresponding fire safety requirements, such places must be installed with a combustible gas alarm system. Safety inspection personnel are equipped with portable toxic and harmful gas detectors to carry out measurement and control technical work on specific places on time to ensure production safety and avoid fire accidents or explosions.

Determine the installation location of the combustible gas alarm control panel based on the proportion of the tested combustible gas compared to the gas

1. When the specific gravity of the gas to be tested exceeds the specific gravity of the gas, the gas detector should be installed at a distance (30-60) cm from the road surface, and the position of the sensor should be downward.

2. When the specific gravity of the gas to be tested is lower than that of the gas, the gas detector should be installed at a distance (30-60) cm from the ceiling, and the sensor should be positioned downward.

After installing the gas detector, it is also necessary to carry out the inspection of the equipment according to the corresponding cycle time to ensure the normal operation of the equipment, so as to ensure that the control panel can work normally with early warning information in the case of flammable gas leakage. When the detector emits an alarm sound, do not use any electrical appliances indoors, even a slight flame may cause an accident; at the same time, open the window, and the personnel quickly evacuated to the outdoors to wait for the firefighters Go ahead and deal with it.

When purchasing a gas detector, the manufacturer will also provide corresponding operation procedures and common problems. It must be installed in strict accordance with the installation method and proper installation position given by the manufacturer. When the equipment is used in the whole process When an abnormal situation is found, it takes time to contact the manufacturer and assign professional and technical personnel to carry out adjustments.

 