How to Maintain a Clarion Optical Biological Microscope

Mar 27, 2024

How to Maintain a Clarion Optical Biological Microscope

 

I. Biological microscope against high heat
Biological microscope is composed of precision machinery and optical lens, due to the different coefficients of thermal expansion of various materials, so the microscope can not be exposed to sunlight, and can not be placed in a place close to the fireplace and heating. It can only be stored at room temperature, and its working temperature range is generally 5℃~40℃.


Second, biological microscope moisture
If the biological microscope is damp for a long time, the lens will be easily mouldy and the surface will be corroded, so it should be stored in a dry environment. At


31℃, the humidity should not be >80%, and the relative humidity should be reduced by 10% for every 3℃ rise in temperature.


Biological microscope dust
Biological microscope dust not only affects the imaging quality, but also dust often with acid, alkali and other corrosive dust particles, easy to corrode the mirror. The hardness of the dust particles in wiping the lens may also be in the mirror surface scratches, damage to the lens. In addition, the dust falls into the mechanical activities of the mechanical part of the mechanical part of the rotation is easy to cause inflexibility, or even damage.


Anti-corrosion of biological microscope
Biological microscope can not contact with acid and alkali substances, and do not put together with volatile chemicals and other harmful drugs, so as not to corrode the lens.


Fifth, biological microscope anti-vibration
Biological microscope is a precision instrument, violent vibration will cause a reduction in precision. It should be held gently, placed on the shelf to be smooth, and used gently.


Wiping the biological microscope
1. If the mechanical device is stained, use a clean soft cloth to wipe it; if it can not be wiped off, use mirror paper or fine silk cloth dipped in a small amount of xylene to wipe it. Should pay attention to not use alcohol and other chemicals, so as not to corrode the surface of the device paint.


2. Optical lens wipe generally use the first blow, after the brush, and then wipe the method. Blow, that is, with a blow balloon (or with a wash ball) to blow off the lens surface of the adherents, but can not use the mouth directly blowing. Blow off when available clean special cleaning brush gently brush. After the above two methods of treatment of the lens surface is still dirt, with a mirror paper slightly dipped in a little xylene gently wipe. If the lens is found to be mouldy long fog, mirror paper can be dipped in a little anhydrous alcohol mixture wipe, but the liquid can not be too much, stay for a short time, so as not to penetrate into the lens caused by corrosion. Oil lens should be wiped in a timely manner after each use, the first dry eraser paper to wipe once or twice, most of the media oil removed, and then use xylene drops wet eraser paper to wipe twice, and then finally dry eraser paper to wipe once.


VII. Biological microscope other
The surface of the optical lens of the biological microscope should not be touched by hand to avoid contamination. Let the device with tension return to its natural state of relaxation after use. Any adjustable parts are best not to let it in extreme position. The power switch should not be switched on and off frequently for short periods of time. Reduce the brightness of the illumination between uses of the microscope. Never leave specimens on the stage for long periods of time, especially if volatile substances are present.

 

4 digital microscope with LCD