Introduce the working principle of an anemometer

 

The basic principle of an anemometer is to place a thin metal wire in a fluid, apply current to heat the wire, and make its temperature higher than the temperature of the fluid. Therefore, the metal wire anemometer is called a "hot wire". When the fluid flows through the metal wire in a vertical direction, it will take away some of the heat from the wire, causing the temperature of the wire to decrease. According to the theory of forced convective heat exchange, a relationship can be derived between the heat dissipated by the hot wire Q and the velocity v of the fluid. A standard hot wire probe consists of two brackets tensioned with a short and thin metal wire. Metal wires are usually made of metals with high melting points and good ductility, such as platinum, rhodium, tungsten, etc. The commonly used wire diameter is 5 μ m and the length is 2 mm; the smaller probe diameter is only 1 μ m and the length is 0.2 mm. According to different purposes, the hot wire probe is also made into double wire, triple wire, oblique wire, V-shaped, X-shaped, etc. In order to increase strength, metal film is sometimes used instead of metal wire. Usually, a thin metal film is sprayed on a thermally insulated substrate, which is called a hot film probe. The hotline probe must be calibrated before use. Static calibration is carried out in a specialized standard wind tunnel, measuring the relationship between flow velocity and output voltage and drawing it into a standard curve; Dynamic calibration is performed in a known pulsating flow field or by adding a pulsating electrical signal to the heating circuit of an anemometer to verify the frequency response of the hot wire anemometer. If the frequency response is poor, corresponding compensation circuits can be used to improve it.


The measurement range of flow velocity from 0 to 100m/s can be divided into three sections: low speed: 0 to 5m/s; Medium speed: 5 to 40m/s; High speed: 40 to 100m/s. The thermal sensitive probe of the anemometer is used for measurements ranging from 0 to 5m/s; The rotary probe of the anemometer has the most ideal effect on measuring flow velocities ranging from 5 to 40m/s; By using a pitot tube, the best results can be obtained within the high-speed range. An additional criterion for correctly selecting the flow velocity probe of an anemometer is temperature. Typically, the temperature range for the thermal sensor of an anemometer is around+-70C. The specialized anemometer's rotary probe can reach 350C. Pitot tubes are used for temperatures above+350C.


maintenance
Wind speed instruments belong to the category of safety protection and environmental monitoring measuring instruments, and are mandatory calibration measuring instruments stipulated by China's Metrology Law. In addition to the corresponding calibration report required for factory sales, it is also necessary to regularly calibrate the instrument at the National Air Conditioning Equipment Quality Supervision and Inspection Center or the Building Energy and Environment Testing Center of the China Academy of Building Research in accordance with the requirements of JJG (Construction) 0001-1992 "Hot Ball Anemometer Calibration Regulations" every year, and adjust all aspects of the instrument according to the statutory calibration certificate issued by them to obtain the best working condition.

 

Windmeter

 

Send Inquiry