Introduction to the Basic Principles and Characteristics of Anemometers

Nov 25, 2026

Introduction to the Basic Principles and Characteristics of Anemometers

 

Basic Principle of the Anemometer

A thin metal wire is placed in the fluid and heated by electric current to a temperature higher than that of the surrounding fluid; hence this type of anemometer is also known as a hot‑wire anemometer. When fluid flows perpendicularly across the metal wire, it carries away part of the heat and lowers the wire temperature. Based on the theory of forced convection heat transfer, a relational expression can be derived between the dissipated heat Q and the fluid velocity v.

 

Characteristics of the Anemometer

LCD display with direct digital readout of pressure, differential pressure and wind speed.

Equipped with Honeywell micro‑pressure sensor from the USA, featuring high resolution, high accuracy and excellent stability.

Portable design. Its circuit adopts Microchip single‑chip microcomputer technology from the USA and provides stable readout function.

Zero drift is unaffected by instrument orientation; the unit is fitted with digital zero adjustment.

Suitable for various working conditions. Shows "H‑H" when readings exceed the measuring range.

Low power consumption; continuous operation for more than 100 hours on a single disposable battery.

Built‑in battery level indicator and temperature display function.

 

Anemometer Operating Instructions

① Before use, check whether the meter pointer aligns with the zero mark. If offset, gently adjust the mechanical zero screw to return the pointer to zero.

 

② Set the CALIBRATION switch to OFF, and set the POWER SELECT switch to the corresponding power source. If using an external power supply, toggle POWER SELECT to EXT, then connect two groups of DC power supplies (1.5 V and 4.5 V) to the external power terminals. Pay attention to polarity to avoid reverse connection. For internal battery power, install batteries in the battery compartment with correct polarity. Insert the probe plug into the socket, place the probe vertically upward and tighten the screw cap to seal the probe.

 

③ Set the CALIBRATION switch to FULL SCALE. Slowly adjust the FULL SCALE trim knob until the meter pointer indicates full scale.

 

④ Set the CALIBRATION switch to ZERO. Slowly adjust the COARSE and FINE knobs to bring the meter pointer to the zero position.

 

⑤ After completing the above steps, gently loosen the screw cap to expose the probe head (probe length can be selected as required) to start measurement. Aim the red dot on the probe head into the oncoming wind. Read the meter value and check the supplied calibration curve to obtain the actual wind speed.

 

⑥ After several minutes of measurement (10 minutes), tighten the screw cap to seal the probe again. Repeat steps ③ and ④ to guarantee measurement accuracy.

 

⑦ Upon completion of measurement, set the CALIBRATION switch to OFF.

 