Introduction to the technical parameters of the high voltage and low voltage clamp-on ammeters
The high and low voltage clamp ammeter has automatic insertion and extraction function, specially designed and manufactured for measuring high voltage current. It adopts new CT technology and mask digital integration technology, and is composed of a dedicated clamp ammeter with a high voltage insulation rod.
If insulation rods are not used, they can also be used as high-precision low-voltage clamp ammeters and leakage ammeters, which can accurately measure currents or leakage currents ranging from 0.1mA to 1000A.
The unique integrated design of the clamp head and guide area of the high and low voltage clamp ammeter ensures high precision, reliability, and stability for uninterrupted testing throughout the year.
Technical parameters
Function: High voltage AC current measurement, low voltage AC current and leakage current measurement, online AC current monitoring
Power supply: DC6V alkaline dry battery (1.5V AAA × 4)
Testing method: clamp CT, integration method
Transmission method: wireless transmission, with a straight-line transmission distance of about 30m
Display mode: 4-digit LCD display, backlight function, suitable for dim places
LCD size 47mm × 28.5mm
Instrument dimensions: width, height, and thickness: 76 × 255 × 31mm3
Jaw size φ 48mm
Sampling rate of approximately 2 times per second
Measurement range 0.1mA~1000A (50/60Hz automatic)
Resolution 0.1mA
Shifting from 0.1mA to 1000A, fully automatic shifting
Test accuracy (23 ℃± 5 ℃, below 80% RH) 0.1mA~299mA: ± 1% ± 3dgt
0.30A~9.99A: ± 1.5% ± 5dgt
10.0A~199.9A: ± 2% ± 5dgt
200A~399A: ± 2.5% ± 5dgt
400A-600A: ± 3% ± 5dgt
601A~1000A: ± 4% ± 5dgt
Testing of lines with voltage below 60KV (operated with 5 insulated poles)
99 sets of data are stored, and the "MEM" symbol indicates during the storage process. The flashing "FULL" symbol indicates that the storage is full
PEAK maintains the automatic high altitude test value. Normally, in test mode, long press the HOLD button until the PEAK light is on, which activates the PEAK hold function
Data retention: In normal testing mode, press the HOLD key to hold the data, and the "HOLD" symbol will be displayed
The "MR" symbol indicates the ability to browse the stored data up and down
Overflow display over range overflow function: "OL A" symbol display
No signal indication: When the receiver does not receive the transmitted signal, the "no --" symbol is dynamically displayed