Methods of Measuring In‑Circuit Resistance with a Digital Multimeter
Before introducing the loaded voltage‑reduction measurement method, the principle of the ratio method for resistance measurement will be explained. Principle of Resistance Measurement by Ratio Method
The section inside the box represents the internal circuit of the multimeter. When the measured resistor Rx is connected across the multimeter terminals, Rx is connected in series with the reference resistor Ro between the V+ pin and the COM pin of the TSC7106 integrated circuit. When the multimeter is switched to the resistance range, the reference power supply Eo of the TSC7106 supplies the test current I to Ro and Rx. The voltage drop VRo across Ro provides the test voltage VRX and acts as the reference voltage VREF for the TSC7106 IC, while VRX serves as the input voltage VIN. The relationship between the input voltage VIN and the reference voltage is: VIN / VRO = VRX / VRO = RX / RO
From this formula, RX = (RO / VRO) · VRX, and VRX = (RX / RO) · VRO. This is the basic principle of resistance measurement by the ratio method. It can be seen from VRX = (RX / RO) · VRO that, within the same resistance range of the multimeter, the smaller the measured resistance, the lower the test voltage across it. In the event of a short circuit (the multimeter displays "000"), RX = 0 and the test voltage VRX = 0. Conversely, as the measured resistance RX increases continuously, the test voltage VRX across it rises accordingly. When the multimeter reads "1000", RX = RO and VRX = VRO. When RX reaches 2RO (full‑scale reading), the overflow symbol "1" is displayed and VRX = 2VRO. For an open‑circuit measured resistor, the test voltage reaches a typical value of approximately 0.65 V.
The open‑circuit voltage (no‑load output voltage) of each resistance range on the DT830A digital multimeter is about 0.65 V. For this reason, it cannot directly measure in‑circuit resistance. This relatively high test voltage may forward‑bias silicon diodes in the circuit under test and make them conduct, interfering with measurement results.
Based on the variation rule between measured resistance and test voltage, we can connect an additional resistor R1 across the V/Ω and COM jacks of the digital multimeter (i.e., across the two test leads) before taking in‑circuit resistance measurements. This pre‑connected load resistor reduces the test voltage of the multimeter on that resistance range. If the resistance value of R1 is properly selected, the maximum test voltage can be limited to 0.3 V or lower.
Silicon diodes are widely used at present, while germanium diodes are rare. Silicon diodes remain cut off at 0.35 V, so their parallel shunting effect on the circuit under test can be ignored (silicon diodes can be regarded as open circuits). This makes the method suitable for measuring the in‑circuit resistance of transistors, known as the loaded voltage‑reduction measurement method.
When measuring in‑circuit resistance with this method, a margin should be reserved below the 0.35 V upper limit for the maximum test voltage of each resistance range; the maximum test voltage is generally controlled at ≤ 0.3 V. The circuit connection for in‑circuit resistance measurement using the loaded voltage‑reduction method is described below.