Safety management regulations of combustible gas detector
The combustible gas detector can quickly, reliably and stably monitor the combustible gas used or produced in industrial production. When the monitoring concentration reaches the preset alarm value of the combustible gas detector, audible and visual alarm will be linked to prompt the field staff to take necessary protective measures, which can effectively prevent the occurrence of combustion and explosion accidents caused by combustible gas. So what are the safety management regulations for combustible gas detectors?
The safety management regulations of combustible gas detector are as follows:
1, must strengthen the use and management of combustible gas detector, combustible gas detector installation rate, utilization rate, intact rate reached 100%.
2. Using combustible gas detector to monitor the leakage and accumulation of combustible gas at the production site is an important means to prevent explosion accidents and must be included in the system management.
3. The location, quantity and mode of setting combustible gas detectors should refer to the equipment of similar devices and equipment at home and abroad, and be implemented according to the production experience and the actual situation of the devices.
4. Where there is the possibility of accidental leakage of combustible gas in newly built, expanded or rebuilt production devices and storage and transportation systems, combustible gas detectors must be equipped according to the principle of "three simultaneities" of simultaneous design, simultaneous construction and simultaneous acceptance. Imported projects and domestic supporting projects should also be equipped with combustible gas detectors in accordance with this principle.
5. The combustible gas detector is managed at three levels: factory, workshop and team. The professional management is given priority to with the mobile office, and the functional departments such as safety, technology, measurement and instrument are jointly responsible.
6, combustible gas detector calibration standard gas, calibration instruments, calibration methods and calibration personnel shall obtain the written permission of the local municipal metrology department.
The related content is shared here for everyone first. The management specification of industrial combustible gas detector aims to standardize the combustible gas detection work in the production and maintenance process of the company and ensure the safety of operation. Its main application scope is suitable for flammable and explosive places, and the gas content in limited space is detection.