+86-18822802390

Simple Digital Multimeter Troubleshooting for Common Issues

Jun 02, 2023

Simple Digital Multimeter Troubleshooting for Common Issues

 

Regarding the troubleshooting methods for common faults of digital multimeters, as we all know, digital multimeter troubleshooting should generally start with the power supply, including visual inspection of digital multimeters, detection of working voltages at all levels, waveform analysis, measurement component parameters and hidden troubleshooting methods, etc.


Troubleshooting methods for common faults of digital multimeter
Digital multimeter troubleshooting should generally start with the power supply. For example, after turning on the power, if the liquid crystal cell displays, you should first check whether the voltage of the 9V laminated battery is too low; whether the battery lead is disconnected.


Finding faults should follow the order of "first inside and then outside, first easy and then difficult". Digital multimeter troubleshooting can be roughly carried out as follows.


1. Appearance inspection
You can touch the battery, resistors, transistors, and integrated blocks to see if the temperature rise is too high. If the newly installed battery heats up, the circuit may be short-circuited. In addition, the circuit should also be observed for disconnection, desoldering, mechanical damage, etc.


2. Detection of working voltage at all levels
Detect the working voltage of each point and compare it with the normal value. First, ensure the accuracy of the reference voltage. It is best to use a digital multimeter of the same model or similar to measure and compare.


3. Waveform analysis
Use an electronic oscilloscope to observe the voltage waveform, amplitude, period (frequency), etc. of each key point of the circuit.


For example, if the clock oscillator starts to vibrate, whether the oscillation frequency is 40kHz. If the oscillator has no output, it means that the internal inverter of TSC7106 is damaged, or the external components may be open.


Observe that the waveform at pin {21} of TSC7106 should be a 50Hz square wave, otherwise, the internal 200 frequency divider may be damaged.


4. Measuring component parameters
For components within the fault range, conduct online or offline measurements, and analyze parameter values. When measuring resistance online, the influence of components connected in parallel with it should be considered.


5. Hidden troubleshooting
Hidden faults refer to faults that appear and disappear from time to time, and the instrument is good and bad. This kind of failure is more complicated, and the common reasons include weak welding of solder joints, looseness, loose connectors, poor contact of transfer switches, unstable performance of components, and continuous breakage of leads.


In addition, it also includes some external factors. For example, the ambient temperature is too high, the humidity is too high, or there are intermittent strong interference signals nearby.

 

3 Multimeter 1000v 10a