What is the service life of gas detectors related to?

Oct 05, 2022

Leave a message

What is the service life of gas detectors related to?


Gas detectors are instrumentation tools for gas leak concentration detection, including: portable gas detectors, hand-held gas detectors, fixed gas detectors, online gas detectors, multi-channel gas detectors, etc. Mainly consists of sensors and the main board circuit of the device itself. We divided it into two main parts, the first part is the sensor part and the second part is the main part of the detector.

Portable Gas Detector

Let's first look at the sensors in the gas detector. Sensors have a fixed service life, and sensors with different principles have different service lives. For example, sensors based on electrochemical principles have a normal design life of two years and need to be replaced when they expire. In general, the number of times the sensor is used has little to do with the storage time. Because electrochemical sensors with electrolyte inside are naturally consumed during sensor placement, they are consumed even when not in use. Therefore, the sensor of the gas detector basically has a fixed replacement cycle, and it must be replaced when it expires. Therefore, we recommend that users do not prepare sensor accessories in advance when using the detector, otherwise it will cause waste and loss.

The second part is the circuit board part of the gas detector. From this point of view, a circuit with reliable design and better materials can basically guarantee the service life of the fuselage for 3-5 years. Some portable gas detectors have an air pump and battery, and the service life is about 2 years.

In short, in the case of normal use of the gas detector, there will be no problems with the circuit board. In most cases, instrument failure is caused by sensor failure, so the life of the gas detector is equal to the life of the sensor. The lifetime of the electrochemical sensor is about 2 years. After two years, it is necessary to test the performance of the instrument and then determine whether to replace the sensor. When replacing the sensor, the gas detector needs to be accurately calibrated.

Online gas detector

It should be noted that each sensor corresponds to a specific detection gas, but no gas detector can be absolutely special. Therefore, when choosing a gas sensor, it is necessary to understand the interference of other gases on the sensor detection as much as possible to ensure its accurate detection of a specific gas.

What types of portable gas detectors are there?

In principle, portable gas detectors can be divided into two types: diffusion type and suction type. As the name suggests, so-called portability is designed for portability, mobility and application flexibility. Mainly include: portable gas detectors, hand-held gas detectors, fixed gas detectors, on-line gas detectors, a variety of gas detectors, we need to consider which portable instrument is suitable for his application when choosing.

Features of Portable Gas Detector:

1. The digital screen can be read directly, which can quickly display the current gas concentration;

2. Through record storage, the sampling interval can be set, and the current concentration data can be automatically recorded as needed;

3. If the gas concentration exceeds the standard, there will be sound and light alarm and vibration prompt;

4. There are rechargeable lithium batteries or replaceable batteries, which can ensure that the battery can be used continuously for more than several hours;

5. Many portable gas detectors are light in weight and small in size.

-1