Working principle of infrared thermometer for temperature measurement of German OPTRIS laser products

Jan 12, 2023

Leave a message

Working principle of infrared thermometer for temperature measurement of German OPTRIS laser products

 

Thanks to its integrated blocking filter for laser radiation, the infrared thermometer optris CT XL 3M is ideally suited for temperature measurement of laser processed products. Additionally, this infrared thermometer is available in a far-focus version that can be combined with laser collimator optics.

In addition, the optris CT XL 3M infrared thermometer can measure very small objects, and due to its fast response time, this thermometer detects faster.

Main parameters of OPTRIS infrared thermometer

Temperature range:

100 °C ~ 1800 °C

Spectral range: 2.3 µm

Response time: 1 ms

​Measurement parameter temperature range 1) (measured by setting key or software):

Spectral range: 2.3 µm

Optical resolution (90% energy):

System Accuracy2) (ambient temperature 23 ±5°C) ± (0.3 % of reading + 2 °C)

Repeatability (ambient temperature = 23 ± 5°C): ± (0.1 % of reading + 1 °C)

Temperature resolution (digital): 0.1K

Exposure time (90% signal)3): 1 ms

Emissivity/Gain (Adjust by setting key or software): 0.100 ~ 1.100

Transmittance/Gain (Adjust by setting key or software): 0.100 ~ 1.100

Signal processing (specific parameters can be adjusted through the setting key or software):

Peak hold, valley hold, average value, extended hold threshold and hysteresis function

Basic parameters Environmental grade: IP65 (NEMA-4)

Environmental rating: IP65 (NEMA-4)

Probe: -40°C ~ 85°C

Electronic box: 0°C ~ 85°C

storage temperature:

Probe: -40°C ~ 125°C

Electronic box: -40°C ~ 85°C

Relative humidity: 10~95%, non-condensing

Vibration (sensor): IEC 68-2-6: 3 G, 11-200 Hz, any axis

Shock (sensor): IEC 68-2-27: 50 G, 11 ms, any axis

weight:

Probe: 150 g

Electronic box: 420 g

Electrical parameter analog output: 0 / 4-20mA, 0-5/10V, thermocouple J, K

Alarm output: 24 V/50 mA (normally open)

Optional: Relays: 2 x 60 V DC/42 V AC; 0.4 A; optically isolated

Digital output (optional): USB, RS232, RS485 (optional), CAN-Bus (controller area network bus), Profibus DP (fieldbus multifunctional slave station design), Ethernet

Output Impedance:

Signal input: Programmable function input for external emissivity adjustment/environmental temperature compensation, trigger (hold function reset)

Cable length: 3m (standard), 8m, 15m

Power supply: DC 8-36 V

Current Consumption: Max 100 mA

1) Object temperature > Probe temperature + 25°C

2) (emissivity) = 1, response time: 1 s

3) Dynamic adaptation at low signal levels

Fields of application of optris CT XL 3M infrared thermometer

The pyrometer optris CT XL 3M is resistant to laser radiation through its blocking filter and is suitable for temperature control during laser processing, for example, laser welding of metals or plastics. The pyrometer optris CT XL 3M is also suitable for laser welding processes.

 

ST490+-5