Working principle of infrared thermometer for temperature measurement of German OPTRIS laser products
Thanks to its integrated blocking filter for laser radiation, the infrared thermometer optris CT XL 3M is ideally suited for temperature measurement of laser processed products. Additionally, this infrared thermometer is available in a far-focus version that can be combined with laser collimator optics.
In addition, the optris CT XL 3M infrared thermometer can measure very small objects, and due to its fast response time, this thermometer detects faster.
Main parameters of OPTRIS infrared thermometer
Temperature range:
100 °C ~ 1800 °C
Spectral range: 2.3 µm
Response time: 1 ms
Measurement parameter temperature range 1) (measured by setting key or software):
Spectral range: 2.3 µm
Optical resolution (90% energy):
System Accuracy2) (ambient temperature 23 ±5°C) ± (0.3 % of reading + 2 °C)
Repeatability (ambient temperature = 23 ± 5°C): ± (0.1 % of reading + 1 °C)
Temperature resolution (digital): 0.1K
Exposure time (90% signal)3): 1 ms
Emissivity/Gain (Adjust by setting key or software): 0.100 ~ 1.100
Transmittance/Gain (Adjust by setting key or software): 0.100 ~ 1.100
Signal processing (specific parameters can be adjusted through the setting key or software):
Peak hold, valley hold, average value, extended hold threshold and hysteresis function
Basic parameters Environmental grade: IP65 (NEMA-4)
Environmental rating: IP65 (NEMA-4)
Probe: -40°C ~ 85°C
Electronic box: 0°C ~ 85°C
storage temperature:
Probe: -40°C ~ 125°C
Electronic box: -40°C ~ 85°C
Relative humidity: 10~95%, non-condensing
Vibration (sensor): IEC 68-2-6: 3 G, 11-200 Hz, any axis
Shock (sensor): IEC 68-2-27: 50 G, 11 ms, any axis
weight:
Probe: 150 g
Electronic box: 420 g
Electrical parameter analog output: 0 / 4-20mA, 0-5/10V, thermocouple J, K
Alarm output: 24 V/50 mA (normally open)
Optional: Relays: 2 x 60 V DC/42 V AC; 0.4 A; optically isolated
Digital output (optional): USB, RS232, RS485 (optional), CAN-Bus (controller area network bus), Profibus DP (fieldbus multifunctional slave station design), Ethernet
Output Impedance:
Signal input: Programmable function input for external emissivity adjustment/environmental temperature compensation, trigger (hold function reset)
Cable length: 3m (standard), 8m, 15m
Power supply: DC 8-36 V
Current Consumption: Max 100 mA
1) Object temperature > Probe temperature + 25°C
2) (emissivity) = 1, response time: 1 s
3) Dynamic adaptation at low signal levels
Fields of application of optris CT XL 3M infrared thermometer
The pyrometer optris CT XL 3M is resistant to laser radiation through its blocking filter and is suitable for temperature control during laser processing, for example, laser welding of metals or plastics. The pyrometer optris CT XL 3M is also suitable for laser welding processes.