Fluke analog/digital multimeters can measure resistance ranging from 0.01 Ω (Model 88) to 32 MΩ, making ignition coil testing highly accurate and straightforward. Ordinary multimeters cannot measure resistance below 1 Ω.

 

Measuring Internal Coil Resistance

If an ignition coil is suspected to be faulty, the resistance of its primary and secondary windings should be checked. Tests shall be performed under both hot and cold engine conditions at every connector. The primary winding of the coil has a low resistance value, while the secondary winding has a much higher resistance. Always refer to the manufacturer's specifications. Typical empirical values are 0 to several ohms for the primary winding and 10 kΩ or higher for the secondary winding.

 

Testing Spark Plug Connections

Spark plugs that have been in service for many years or show signs of potential failure should be inspected. Not all spark plug cables are marked with production dates. High operating temperatures may cause the spark plug shell to seize to the plug itself; removing the spark plug may damage the fine, brittle wires inside the insulator. Therefore, rotate the plug back and forth repeatedly before removal. If a fault is suspected, measure resistance while slowly twisting and rotating the cable. The resistance value is approximately 30 kΩ per meter, which varies with cable type and may be substantially lower in some cables. Compare readings with other spark plug cables on the same engine for accurate judgment.

 

Capacitors

Fluke analog/digital multimeters can also test automotive capacitors. The deflection of the analog needle indicates that the multimeter is charging the capacitor. You will observe resistance changing from zero toward infinity. Test the capacitor in both polarities and check its performance under both hot and cold conditions.

 

Testing Capacitor Leakage

Use the resistance range of the multimeter to test capacitor leakage. When the capacitor is fully charged, the resistance should rise to infinity. Any finite resistance reading indicates that the capacitor requires replacement. The capacitor must be disconnected from the vehicle circuit before testing.

 

Hall‑Effect Position Sensors

Hall‑effect sensors have replaced many contact‑type ignition points on distributor plates and are used to directly detect the position of the crankshaft and camshaft in distributor‑less ignition systems. They signal the ECU when to trigger coil ignition. A Hall‑effect sensor generates a voltage proportional to the magnetic field strength passing through it, which can be produced by a permanent magnet or electric current.

 

Testing Hall‑Effect Sensors

First verify the supply voltage from the battery. Hall‑effect sensors require a power supply, unlike solenoid valves. To test the sensor, connect the +12 V battery lead to the power terminal, and use the multimeter to measure the signal output voltage relative to ground. Insert a shim between the sensor and the magnet assembly and observe whether the analog needle of the multimeter deflects. The reading should vary between 0 V and 12 V.

 

Magnetic Position Sensors

A magnetic position sensor consists of a coil wound around a permanent magnet. Clearance between the pickup and reluctor is critical. Its typical specification ranges from 0.8 mm to 1.8 mm.

 

Testing Pulses from Magnetic Distributors

Remove the distributor from the ignition module. Set the multimeter to DC voltage mode and connect the probes to the ignition terminal. Pulses will appear on the analog needle as the engine is cranked. If no pulses are present, the reluctor wheel or magnetic pickup may be defective. The same method can be used to test other magnetic position sensors.

 