DC Voltage Measurement Circuit of Analog Multimeter
How does the DC voltage measurement circuit of an analog multimeter operate? The following takes the DC voltage measurement circuit of the MF9 multimeter as an example.
Set the selector switch to the DC voltage "−" position, and the DC voltage measurement circuit shown in the diagram is formed. It can be seen from the DC voltage measurement circuit of the MF9 multimeter that the movable contact blades "a" and "b" of the selector switch connect the fixed contacts 5, 6, 7, 8, 9 and 10 to metal strip A or B respectively, so as to obtain six different DC voltage measurement ranges. Only the lowest 0.5 V range is equipped with an individual multiplier resistor; the other ranges adopt a circuit with shared multiplier resistors. In this circuit, the meter movement remains in parallel with the shunt resistors used for current ranges, and is then connected in series with multiplier resistors. This is equivalent to a meter movement with relatively low sensitivity and low internal resistance connected in series with multiplier resistors. The advantage is that the DC voltage range and AC voltage range can share the same multiplier resistor components. The circuit analysis is as follows:
DC Voltage Measurement Circuit of MF9 Multimeter
① When the movable contact blades "a" and "b" of selector switch A connect to contact "5", only a 5.5 kΩ multiplier resistor is connected in series with the meter movement. The current path is: "+" → A → a → b → 5.5 kΩ → 2.33 kΩ → 1.4/2 kΩ → microammeter → "−". Since only one 5.5 kΩ voltage-dividing resistor is connected in series, this is the smallest range, used for measuring DC voltage of 0.5 V and below.
② When the movable contact blades "a" and "b" of selector switch B connect to fixed contact "6", the path of the multiplier resistors in series with the meter movement is: "+" → 35.5 kΩ → a-b → 2.33 kΩ → 1.4/2 kΩ → microammeter → "−". The total series multiplier resistance is relatively small, so the range is comparatively low, corresponding to the 2.5 V DC voltage range.
③ When movable contact blades "a" and "b" connect to contact "7", the path of the multiplier resistors in series with the meter movement is: "+" of selector switch A → 35.5 kΩ → 10 kΩ → 150 kΩ → contact "7" → a-b → 2.33 kΩ → 1.4/2 kΩ → microammeter → "−". Compared with the 2.5 V range, an additional 150 kΩ resistor is connected in series, so the range is extended to the 10 V range.
④ When sliding blade V' and blade "b" connect to fixed contact "8", the resistors in series with the meter movement are: 35.5 kΩ → 10 kΩ → 150 kΩ → 800 kΩ → a-b → B → 2.33 kΩ → 1.4/2 kΩ → microammeter → "−". An extra 800 kΩ resistor is added to the series multiplier resistors compared with the 10 V range, so the range becomes 50 V. By the same logic, you may analyze the 250 V and 500 V ranges by yourself.
In summary, multi-range voltage functions adjust the measuring range by changing the resistance value of the multiplier resistors connected in series with the meter movement branch. The more multiplier resistors are connected in series (the larger the total resistance value), the wider the measurement range.