+86-18822802390

Multimeter Test for Polarity and Integrity of Ordinary Diodes

Nov 10, 2026

Multimeter Test for Polarity and Integrity of Ordinary Diodes

 

Testing Principle

Based on the unidirectional conductivity of a diode: a good diode has low forward resistance and high reverse resistance. The larger the difference between these two values, the better. If the values are close, the diode performs poorly or is damaged. For measurement, use the ohm range of the multimeter. Generally, select the R×100 or R×1k range instead of R×1 or R×10k. The R×1 range supplies excessive current, which may burn out the diode; the R×10k range has too high internal supply voltage and may break down the diode.

 

Measurement Method

Connect the two test probes to the two electrodes of the diode and record the resistance reading. Then swap the probes and measure again, and record the second reading. If the two readings differ greatly, the diode is in good condition. From the measurement with the smaller resistance value (forward connection), the electrode connected to the black test probe is the anode of the diode, and the one connected to the red test probe is the cathode. This is because the positive terminal of the multimeter's internal battery is connected to the "-" jack, and the negative terminal of the internal battery is connected to the "+" jack.

 

If both readings are very low, the diode is broken down. If both readings are very high, the diode has an internal open circuit. If there is little difference between the two readings, the diode has poor performance. Diodes in these conditions cannot be used.

It should be noted that the volt-ampere characteristic of a diode is nonlinear. Different resistance ranges of the multimeter will yield different resistance readings for the diode. In practical operation, the current passing through the diode will be larger, so the resistance presented by the diode will be lower.

 