Multimeters are widely used, and there is a great variety of electronic components. For electronics enthusiasts, it is very helpful to make full use of a multimeter. A resistor is one of the most commonly used components and comes in many types, such as metal film resistors, wirewound resistors, piezoresistors, photoresistors and so on. This article uses several experiments to help you become more familiar with multimeter operation, especially the resistance range.
① When measuring resistors less than 50 Ω Turn the multimeter dial to the R×1 range. Connect the test probes to the two leads of the resistor. The pointer should deflect rightward and point to the nominal value of the resistor. If the measured value differs greatly from the nominal value, perform zero adjustment for this range first. If zero adjustment is correct, the resistor has an incorrect resistance value and is defective.
② When measuring resistors from 50 Ω to 500 Ω The range is different from that for 50 Ω resistors. Switch the multimeter to the R×10 range. The probe connection method is the same as for 50 Ω resistors. Note that the reading must be multiplied by 10 to get the correct resistance value. If the measurement on the R×10 range is inaccurate, perform zero adjustment on this range first, then repeat the above steps to obtain the correct resistance.
③ When measuring resistors from 500 Ω to 1 kΩ Set the multimeter to the R×100 range. The wiring method remains the same as above. Multiply the reading by 100 to get the actual resistance value.
④ When measuring resistors from 1 kΩ to 50 kΩ First, set the multimeter to the R×1k resistance range. The wiring method is identical to the previous three cases, and the reading should be multiplied by 1 kΩ. If the pointer does not move, check the power supply first, primarily verify whether the multimeter battery is installed properly. If the pointer deflects too far to the left while using the resistance range, the selected range is improper. Re-select the range and repeat the measurement steps for an accurate reading.
From the four resistor measurement tests above, we can see that the probe connection method is identical for all resistance measurements: simply connect the two test probes arbitrarily to the two leads of the resistor (see figure below). When measuring resistors, you should know the approximate resistance value in advance and select the corresponding range. If the resistance is unknown, start with the highest range. If the reading is too large, gradually switch down to lower ranges to avoid damaging the multimeter.