Troubleshooting Common Problems of Digital Multimeters
① In most cases, damage to digital multimeters is caused by incorrect function range selection. For example, if the resistance range is selected while measuring AC mains voltage, internal components of the meter will be damaged instantly once the probes touch the live mains. Therefore, always verify that the measurement range is correct before taking measurements. After use, set the selector switch to the 750 V AC or 1000 V DC position. This prevents damage to the digital multimeter even if incorrect parameters are measured by mistake next time.
② Some digital multimeters are damaged when the measured voltage or current exceeds the rated range. For instance, measuring mains voltage on the 20 V AC range can easily destroy the AC amplifier circuit and disable the AC measurement function. Excessive DC voltage applied during DC voltage measurement may also lead to internal circuit faults. If the actual current exceeds the range during current measurement, usually only the internal fuse will blow without further damage. When measuring voltage with an unknown approximate value, start on the highest voltage range, read the value and switch down to an appropriate range for a more accurate reading. If the voltage far exceeds the maximum measuring range of the multimeter, high‑voltage high‑impedance test probes must be used separately. Typical applications include measuring anode high voltage and focus high voltage in black‑and‑white or color televisions.
③ Most digital multimeters have a maximum DC voltage range of 1000 V. Generally, voltages below 1000 V will not damage the meter. Voltages above 1000 V are very likely to cause damage. Note that the maximum measurable voltage varies among different multimeter models. For voltages beyond the meter's range, a resistive voltage divider network can be used. When measuring DC high voltage from 400 V to 1000 V, ensure firm, stable contact between the probes and test points with no shaking. Shaky contact may not only damage the meter and produce inaccurate readings, but can also cause the display to go blank in severe cases.
④ Never measure resistance on an energized circuit.