Experts will help you solve the small problem with the pH meter electrode
What are the materials of electrodes? The pH electrode shell generally adopts two types: PC plastic (polycarbonate) shell and glass shell. The PC shell is resistant to collision and impact, but suitable for temperatures below 80oC. And it is prone to corrosion in high alkaline solutions and some media. The glass casing is suitable for temperatures between 0-150oC and is generally not corroded except for hydrofluoric acid solution, but is prone to collision damage. Stainless steel, polytetrafluoroethylene, metal, etc.
What are the different uses of different materials for electrodes? PC plastic, polycarbonate, PC shell is resistant to collision and impact, but suitable for temperature<80oC PTFE electrodes, corrosion resistance, commonly known as plastic king, except for some organic solvents. Glass electrodes are resistant to high temperatures, corrosion (except for hydrofluoric acid), and are easy to break. If there is a medium containing HF but not corrosive, stainless steel electrodes can be used at temperatures between 0-100 degrees Celsius; If the medium contains organic solvents, polytetrafluoroethylene electrodes can be used, which can withstand high temperatures at around 280 degrees Celsius; The pH electrode can reach a high temperature of 130 degrees Celsius. For temperatures above 130 degrees Celsius, it is recommended to use imported electrodes.
3. What is the lifespan of an electrode under normal use?
Generally, electrodes are used for six months to a year, depending on the operating conditions, and some may be used for one and a half to two years. Imported products may last for 3-5 years, but they are expensive!
How to protect the electrodes? (1) The glass film at the lower end of the glass electrode is prone to breakage and should not come into contact with hard objects. (2) When using for the first time, the spherical glass film should be soaked in distilled water for day and night. When not in use, it should also be soaked in distilled water to simplify the soaking procedure for the next use. (3) When measuring strong alkaline solutions, the operation should be carried out as soon as possible. After the measurement is completed, it should be washed with water immediately to prevent the alkaline solution from corroding the glass film. (4) The glass film must not be contaminated with oil. If this situation occurs, Gangfu should first immerse it in lees, then put it into ether or carbon tetrachloride, and then transfer it to alcohol. After that, rinse with water and immerse it in water. (5) The organic glass tube on the electrode plug has excellent insulation performance and should not come into contact with chemicals or oil stains.