Using a Multimeter to Easily Troubleshoot Poor Contact of Potentiometers

 

When testing a potentiometer with a multimeter, select an appropriate range according to the nominal resistance of the potentiometer. To measure its nominal resistance: set the multimeter to a suitable ohm range, connect the two test probes to terminals "1" and "3" of the potentiometer. The pointer should point to the corresponding resistance scale. If the pointer stops at a fixed reading and does not move any further, it means the resistance body of the tested potentiometer has already been open‑circuited. If the pointer reading is unstable, the potentiometer has poor contact. Below is the detailed operating procedure.

 

To check whether the wiper of the potentiometer makes good contact with the resistance body: while measuring resistance with the multimeter, rotate the potentiometer shaft and observe the movement of the pointer. For measurement, set the multimeter to the ohm range. Connect one probe to the wiper terminal "2", and the other probe to either terminal "1" or "3" of the resistance body, to measure the resistance of R12 or R23. Meanwhile, rotate the potentiometer shaft counterclockwise and then clockwise, and watch the multimeter pointer. For a good potentiometer, the pointer should move smoothly. If the pointer stays still or jumps erratically, the wiper of this potentiometer has poor contact with the resistance sheet.

 

For a potentiometer with an integrated switch, you also need to verify whether the switch functions properly. Use the ohm range of the multimeter, connect the two probes to the switch terminals "4" and "5". Rotate or pull the potentiometer shaft to toggle the switch between the

 

ON and OFF states, and observe the pointer. When switched ON, the pointer should deflect to the far right (resistance = 0 Ω); when switched OFF, the pointer should deflect to the far left (infinite resistance). Repeat the test several times to check for intermittent poor contact of the switch.

 

When using a digital multimeter to measure the potentiometer, the reading is 56.9 kΩ, which matches the sum of the marked values 21.7 kΩ and 35.2 Ω shown in the diagram.

 

Key Notes

Select the proper range. Connect the probes to terminals 1 and 3 to measure the nominal resistance across both ends. Check the contact of the sliding arm. While measuring, watch the reading, then test the switch. Perform zero adjustment; zero drift is normal.

 

2 Ture RMS Multimeter

Send Inquiry